Devices
At the RIZ you will find various up-to-date devices for certain techniques for general use by TiHo members and, if applicable, guests. All equipment can be used for S2 experiments.
If you are interested or have any questions, please contact:
Dr. Tina Basler
Stephanie Geveke, BTA (for technical questions)
Apotome
Axio Imager M2 with ApoTome (Zeiss)
for shots of „confocal-like“ fluoreszenz pictures with highly reduced diffused light
on an anti-vibration-basis.
Fluoreszenz-light: HXP120 white light source
transmitted light: Halogen-lamp HAL 100
Via the black/white camera the pictures can be transferred directly into the Software „ZEN2 blue“ to regard and work on them.
Additional color camera for histology.
Available objektives:
Plan Apochromat 10x / 0,3
Plan Apochromat 63x / 1,4 Oil
Plan Apochromat 20x / 0,8
Plan Apochromat 100x/ 1,4 Oil
Plan Apochromat 40x / 0,95 with correcting ring
Available filtersets:
38-> excitation BP 470/40 ; beamsplitter FT 495 ; emission BP 525/50
43-> excitation BP 550/25 ; beamsplitter FT 570 ; emission BP 605/70
49-> excitation G365 ; beamsplitter FT 395 ; emission BP 445/50
50-> excitation BP 640/30 ; beamsplitter FT 660 ; emission BP 690/50
Bioanalyzer
2100 Bioanalyzer System (Agilent)
Chemidoc Imaging
Chemidoc MP (Biorad)
with RYB-Light, Fluorescence and Chemiluminescence
Possibility of transmitted light with white light convertion screen
For detection of DNA (syBr-green,…), proteins (Coomassie, silver staining or stainfree) and fluorescence dyes
Digitization of the images and evaluation
ELISpot reader
CTL S6 Analyzer (Immunospot)
FACS
FACS Attune NxT with Autosampler
FACS analysis for single-cell-suspensions of fixed and non-fixed S2-samples.
Compatible with classical FACS-tubes or Eppis as well as with automatic samplic of different plates (96 well etc.).
Attune works based on hydrodynamic and additional acustic focussing.
Possible throughput rate: 1 ml/min
Excitation Laser violett (405nm) -> Detection 440/50 ; 512/25 ; 603/48 ; 710/50
Excitation Laser blue (488nm) -> Detection 530/30 ; 590/40 ; 695/40
Excitation Laser yellow (561nm) -> Detection 585/16 ; 620/15 ; 695/40 ; 780/60
Excitation Laser red (637nm) -> Detection 670/14 ; 720/30 , 780/60
Special pump mechanistics guarantee the input of specified quantities of sample volumes. Samples not used can be recycled and fed back.
FACS Fortessa X20
FACS analysis for single-cell-suspensions of non-infectious S2-samples.
Compatible with BD FACS-tubes as well as with S2-samples with automatic samplic system HTS for plates (96 well).
Separation of signals highly efficient by mirror System
Excitation Laser violett (405nm) -> Detection 780/60; 710/50; 670/30; 610/20; 525/50; 450/50
Excitation Laser red (640nm) -> Detection 780/60; 730/45; 670/30
Excitation Laser blue (488nm) -> Detection 780/60; 710/50; 610/20; 575/25; 530/30
Life Cell Imaging
Microscope with Climate Chamber for Life-Cell-Imaging (Nikon)
Fluorescence mikroscope TE 300 (NIKON) with climate chamber, invert and motorized for life cell imaging.
Climate chamber CO2 and temperature adjustable.
Holder for different plates and slides.
Via the black/white camera the pictures can be transferred directly into the Software „NIS“ to regard and work on them.
Available objektives:
Plan Fluor 10x / 0,3
S-Plan Fluor 20x / 0,45 EL WD
S-Plan Fluor 40x / 0,6 EL WD
S-Plan Fluor 60x / 1,4
additional x1,5 optical magnification available for all objectives
Available filtersets:
EX: 377/50 DM:409 BA: 447/60 BP (DAPI)
EX: 472/30 DM:495 BA: 520/35 BP (FITC, EGFP)
EX: 562/40 DM:593 BA: 624/40 BP (Alexa568, mCherry, TxRed)
EX: 628/40 DM:660 BA: 692/40 BP (Cy5)
EX: 545/25 DM:565 BA: 605/70 BP (Cy3)
Multi-mode Plate Reader
INFINITE F200 PRO OR SPARC (TECAN)
Plate reader with filters for absorption, immunofluorescence, polarisation and luminescence (Luziferase assay).
Adjustable and heatable chamber, one with gas and climate chamber (CO2 and N2) for hypoxia conditions.
Injection of reagents before and during measurement possible.
All chambers can be temperated (->+42°C) and shaking
ZZ first floor:
with injector -> possibility to add liquids during measurements
Absorption (optic can 230 – 1000nm), filter for: 405(10), 450(10), 595(10), 620(10)
Fluorescence: (optic 230 – 850nm), filter for: 485(50)/ 535(50)
incl bottomreading and F. Polarisation
Luminescence module for luciferase-assay and Multicolor luminescence, Filter 1+2 in green, Magenta, Blue1, Green1
ZZ 2nd floor:
with gas (CO2 + N2), humidity chamber and lid lifter for long term measurement
Absorption Monochromator 200-1000 nm (each nm possible)
Fluorescence: (optic 230 – 850nm), Filter for Ex: 380(20), 485(20)/ 550(10) (Combination free to choose), Filter for Em: 535(25), 620(20), 670(40), 460(20), incl bottomreading (No fluorescence polarization, no luminescence)
FI S3:
Absorption (optic can 230 – 1000nm), filter for: 450Ex, 405Ex, 620Ex, 595Ex
Fluorescence (optic 230 – 850nm), filter for 485(20)/535(25), 550(10)/620(20), 400(20)/505(20)
incl bottomreading and F. Polarisation
Luminescence module for luciferase-assay and Multicolor luminescence
Injector
FI S3e:
Absorption Monochromator 200-1000 nm (each nm possible)
Fluorescence: (optic 230 – 850nm), we have filter for excitation 560(20), 485(20), 495(10), 430(20), 360(35) and for emission 620(10), 535(25), 540(25), 485(20), 465(35), 520(10) incl bottomreading (No fluorescence polarization)
Luminescence (no multicolor)
Injector
Multiscan
only for Absorptions of 200-100 nm
O2 Glove Box
O2 Control in vitro Glove Box (Coy)
For Tissue Culture.
Perform incubation, culture maintenance & analysis in the same environment.
Qiacube (HT)
Qiacube - Automatic Extraction of DNA & RNA
Up to 12 columns (Qiagen systems).
Ideal conditions for comparable handling of different samples allowing reproducable results in less time. Possible for isolation of high quality DNA and RNA from different samples like blood, tissue or gels.
Qiacube HT roboter
Extraction of DNA, RNA and more on a 96-well-format from different types of sampes (tissue, blood) for Qiagen-kits "Qiacube HT".
Parallel processing of up to 96 samples (units of 8).
Vacuum system with a column insert for high throughput and standardised conditions in less time.
Real-Time Cycler
Light cycler 96 (Roche)
96-well format
Aria MX (Agilent)
96-well format
Ultracentrifuges & High-Power Centrifuges
Ultracentrifuge Optima XPN (Beckman)
rotors:
70Ti Max 70.000UPM/504.000xg 8 x 35,5 ml
SW40Ti Max 40.000UPM/285.000xg 6 x 14 ml
SW60Ti Max 60.000UPM/485.000xg 6 x 4 ml
SW32Ti Max 32.000UPM/175.000xg 6 x 38,5 ml
Avanti-J-26S XP (Beckman)
big centrifuges also for larger amounts of liquids
Rotors:
JA25.50 Max.25.000 UPM/75.600xg 8 x 50 ml
JLA16.250 Max.16.000 UPM/38.400xg 6 x 250 ml
JLA10.500 Max.10.000 UPM/18.600xg 6 x 500 ml